PPG INDUSTRIES INC -- SPEEDHIDE WHITE/PASTEL, 6-1110 -- 8010-00N036106
=====================  Product Identification  =====================

Product ID:SPEEDHIDE WHITE/PASTEL, 6-1110
MSDS Date:11/25/1992
FSC:8010
NIIN:00N036106
=== Responsible Party ===
Company Name:PPG INDUSTRIES INC
Address:4325 ROSANNA DR
Box:9
City:ALLISON PARK
State:PA
ZIP:15101
Country:US
Info Phone Num:412-492-5555
Emergency Phone Num:304-843-1300
CAGE:DO542
=== Contractor Identification ===
Company Name:PPG INDUSTRIES INC
Box:UNKNOW
CAGE:PPGXX
Company Name:PPG INDUSTRIES INC. COATINGS & RESINS GP
Address:4325 ROSEANNA DR PO BOX 9
Box:9
City:ALLISON PARK
State:PA
ZIP:15101
Phone:412-492-5555
CAGE:DO542

=============  Composition/Information on Ingredients  =============

Ingred Name:VENT:BELOW STATED LIMIT, & TO REMOVE DECOMPOSITION PRODUCTS
    DURING WELDING OR FLAME CUTTING.
RTECS #:9999999ZZ

Ingred Name:EYE PROT:& FULL LENGTH FACESHIELD .
RTECS #:9999999ZZ

Ingred Name:TITANIUM OXIDE; (TITANIUM DIOXIDE)
CAS:13463-67-7
RTECS #:XR2275000
Fraction by Wt: 20-25%
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:10 MG/M3 TDUST

Ingred Name:CALCIUM CARBONATE
CAS:1317-65-3
RTECS #:EV9580000
Fraction by Wt: 5-10%
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:10 MG/M3 TDUST

Ingred Name:CARBONIC ACID, CALCIUM SALT (1:1); (CALCIUM CARBONATE)
CAS:471-34-1
RTECS #:FF9335000
Fraction by Wt: 15-20%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:SOLVENT NAPHTHA (PETROLEUM) MEDIUM ALIPHATIC; (MEDIUM
    ALIPHATIC SOLVENT NAPHTHA)
CAS:64742-88-7
Fraction by Wt: 25-30%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:FILM FORMERS, RESINS, & ADDITIVES
Fraction by Wt: 20-25%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:SUPDAT:INHALING MASSIVE QTYS OF TITANIUM DIOXIDE DUST IN
    LONG-TERM STUDY DEVELOPEED LUNG TUMORS. STUDIES W/HUMANS(ING 7)
RTECS #:9999999ZZ

Ingred Name:ING 6:INVOLVED IN MANUFACTURE OF THIS PIGMENT INDICATE NO
    INCR RISK OF CANCER FROM EXPOS. POTNTL FOR INHAL OF (ING 8)
RTECS #:9999999ZZ

Ingred Name:ING 7:TITANIUM DIOXIDE DUSTS FROM COATINGS IS VERY LTD.
    SINCE OVEREXPS ARE NOT EXPECTED, THERE IS NO SIGNIFICANT (ING 9)
RTECS #:9999999ZZ

Ingred Name:ING 8:HAZARD FOR MAN.
RTECS #:9999999ZZ

Ingred Name:RESP PROT:TO DETERMINE TYPE OF AIRBORNE CONTAMS AGAINST
    WHICH RESP IS EFTIVE & HOW IT IS TO BE PROPERLY FITTED.
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INGEST:HARMFUL/FATAL IF
    SWALLOWED. EYE CONT:CAUSES IRRIT. REDNESS, ITCH, BURNING SENSATION
    & VISUAL DISTURBS MAY INDICATE EXCESSIVE CONT. SKIN CONT:MAY CAUSE
    MOD IRRIT. DRYNESS, ITCH, CRACKING,  BURNING, REDNESS & SWELL ARE
    CNDTNS ASSOC W/EXCESSIVE CONT. INHAL:VAP & SPRAY MIST MAY BE
    HARMFUL IS (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:INHALED. VAP IRRITS EYES, NOSE &
    THROAT. RPTD EXPOS TO HIGH VAP CONCS MAY CAUSE IRRIT OF RESP SYS &
    PERM BRAIN & NERV SYS DMG. INTENTIONAL MISUSE BY DELIB CONC &
    INHALING CONTENTS CAN BE HARM FUL/FATAL. EYE WATERING, HDCHS, NAUS,
    DIZZ & LOSS OF COORD ARE INDICATIONS THAT SOLV LEVELS ARE TOO HIGH.
    (SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:INGEST:DO NOT INDUCE VOMIT. EYES:FLUSH IMMED W/PLENTY OF
    WATER FOR AT LST 15 MINS. SKIN:FLUSH IMMED W/PLENTY OF WATER
    FOLLOWED BY WASHING W/SOAP & WATER. INHAL:REMOVE TO FRESH AIR.
    APPLY ARTF RESP & O THER SUPPORTIVE MEASURES AS REQD. NOTE:IF
    INGEST, ANY TYPE OF OVEREXP/SYMPS OF OVEREXP OCCUR DURING/FOLLOWING
    USE OF THIS PROD, CONT POIS CTL CTR, EMER ROOM/MD IMMED; HAVE MSDS
    INFO AVAILABLE.

=====================  Fire Fighting Measures  =====================

Flash Point Method:PMCC
Flash Point:107F,42C
Lower Limits:1%
Extinguishing Media:USE NFPA CLASS B EXTINGS (CARBON DIOXIDE, DRY
    CHEM/UNIVERSAL AQ FILM FORMING FOAM) DESIGNED TO EXTING NFPA
    CLASS(SUPDAT)
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP .
    WATER SPRAY MAY BE INEFT. WATER SPRAY MAY BE USED TO COOL CLSD
    CNTNRS TO PVNT PRESS BUILD-UP & POSS(SUPDAT)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLSD. ISOLATE FROM
    HEAT, ELEC EQUIP, SPKS & OPEN FLAMES. CLSD CNTNRS MAY EXPLODE WHEN
    EXPOS TO EXTREME HEAT. DO NOT APPLY ON HOT (SUPDAT)

==================  Accidental Release Measures  ==================

Spill Release Procedures:PROVIDE MAX VENT. ONLY PERS EQUIPPED W/PROPER
    NIOSH/MSHA APPRVD RESP & SKIN & EYE PROT SHOULD BE PERMITTED IN
    AREA. REMOVE ALL SOURCES OF IGNIT. TAKE UP SPILLED MATL W/SAWDUST,
    VERMICULITE/OTHER ABSOR B MATL & PLACE INTO CNTNRS FOR DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:DO NOT STORE >120F. STORE LG QTYS IN
    BLDGS DESIGNED & PROTECTED FROM STOR OF NFPA CLASS II COMBUST LIQS.
    CNTNRS SHOULD BE GROUNDED WHEN POURING.
Other Precautions:IF THIS MATL IS PART OF A MULTIPLE COMPONENT SYS,
    READ MSDS(S) FOR OTHER COMPONENT(S) BEFORE BLENDING AS RESULTING
    MIXT MAY HAVE HAZS OF ALL OF ITS PARTS. AVOID FREE FALL OF LIQS IN
    EXCESS OF A FEW IN CHES.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:OVEREXP TO VAPS MAY BE PREVENTED BY ENSURING
    VENT CONTROLS, VAP EXHST/FRESH AIR ENTRY. NIOSH/MSHA APPRVD
    (TC-23C-) AIR PURIFYING/AIR SUPPLIED (TC-19C-) RESPS MAY ALSO
    REDUCE EXPOS. READ RESP MFR'S INS TRUCTIONS & LITERATURE
    CAREFULLY(ING 10)
Ventilation:PROVIDE GEN DILUTION/LOC EXHST VENT IN VOL & PATTERN TO
    KEEP CONC OF INGS BELOW LOWEST SUGGESTED EXPOS LIMS, LEL(ING 11)
Protective Gloves:NITRILE RUBBER/NEOPRENE RUBBER GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS(ING 12)
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
    ANSI DESIGN CRITERIA . WEAR PROT CLTHG, INCLUDING IMPERMEABLE
    APRON.
Work Hygienic Practices:CLEAN OR DISCARD CONTAMINATED CLOTHING & SHOES.
Supplemental Safety and Health
EXTING MEDIA:II COMBUST LIQ FIRES. FIRE FIGHT PROC:AUTOIGNIT/EXPLO WHEN
    EXPOS TO EXTREME HEAT. IF WATER IS USED, FOG NOZZ ARE PREF. EXPLO
    HAZ:SURFS. TOX GASES MAY FORM WHEN PROD IS CONTACTED BY FLAME/ HOT
    SURFS. EFTS OF OVEREXP:CHRONIC:AVOID LONG TERM & RPTD CONT. THIS
    PROD CONTAINS TITANIUM DIOXIDE. ANIMALS (ING 6)

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:>212F,>100C
Vapor Pres:2.3
Vapor Density:HVR/AIR
Spec Gravity:1.36
Evaporation Rate & Reference:17 (BUOAC=100)
Solubility in Water:0.2%
Appearance and Odor:VISCOUS LIQUID W/ODOR CHARACTERISTIC OF SOLVENTS
    LISTED IN INGREDIENTS.
Percent Volatiles by Volume:47.2

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT W/STRONG ALKALIES, STRONG MINERAL ACIDS OR STRONG
    OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:MAY PRDCE HAZ DECOMP PRODS WHEN
    HEATED, WELDING, BRAZING/FLAME-CUTTING. MAY PRDCE FUMES INCL:
    CARBON MONOXIDE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:WASTE MATL MUST BE DISPOSED OF I/A/W FED, STATE,
    PROVINCIAL & LOCAL ENVIRON CONTROL REGS. EMPTY CONTAINERS SHOULD BE
    RECYCLED OR DISPOSED OF THROUGH AN APPROVED WASTE MANAGEMENT
    FACILITY.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.